UFC200 Fan-kit – AM checking

  1. Open Left door and locate the Fan kit
  2. Check the fans for mechanical damaged or contamination on the fan body and blades.
  3. Check the functionality of the fans while charge CCS guns separately.
  4. If the fans don't spin during CCS charging, check the connection of terminal XR1-16 according to Figure 3.

Note: Both fans should be active as soon as any of CCS guns is active


Figure 1. Fan-kit location


A machine with fans and wires<br><br>AI-generated content may be incorrect.


Figure 2. Fan-kit



A metal box with black fans<br><br>AI-generated content may be incorrect.


Figure 3. Terminal XR1-16
 

 
Disclaimer Notice
By using Delta Electronics (Netherlands) B.V. and affiliates website and its technical information, you agree to be bound by the terms of this warranty disclaimer
 
          
About Delta
Delta, founded in 1971, is a global provider of power and thermal management solutions. Its mission statement, "To provide innovative, clean and energy-efficient solutions for a better tomorrow," focuses on addressing key environmental issues such as global climate change. As an energy-saving solutions provider with core competencies in power electronics and automation, Delta's business categories include Power Electronics, Mobility, Automation, and Infrastructure.